Please use this identifier to cite or link to this item:
http://dspace.unimap.edu.my:80/xmlui/handle/123456789/27024
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Paulraj, Murugesa Pandian, Dr. | - |
dc.contributor.author | Abdul Hamid, Adom, Prof. Dr. | - |
dc.contributor.author | Tung, Kai Xu | - |
dc.contributor.author | Subramaniam, Kamalraj | - |
dc.date.accessioned | 2013-07-23T12:49:49Z | - |
dc.date.available | 2013-07-23T12:49:49Z | - |
dc.date.issued | 2012-11-20 | - |
dc.identifier.citation | p. 67-70 | en_US |
dc.identifier.uri | http://dspace.unimap.edu.my/123456789/27024 | - |
dc.description | Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012 organised by technical universities under the Malaysian Technical Universities Network (MTUN), 20th - 21st November 2012 at Hotel Seri Malaysia, Kangar, Perlis. | en_US |
dc.description.abstract | This paper presents the design and construction of a low power application-specific EEG bio-potential multichannel amplifier with high common mode rejection ratio (CMRR) and high input impedance. The bio-potential amplifier designed was band-limited specifically (0-40Hz) to control the power-line noise interferences and intends to record event-related and evoked potentials of the somatosensory stimuli. The fabricated EEG bio-potential amplifier has a CMRR of 140 dB below 100 Hz with an input impedance of 300 MΩ. The designed EEG bio-potential amplifier circuit meets the required specification of low power consumption and high gain. The EEG bio-potential amplifier was tested on young healthy subjects and the results were compared to those obtained using commercially available EEG amplifiers. The observed results with the designed bio-potential amplifier are able to provide significant information for biomedical engineering research. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Malaysian Technical Universities Network (MTUN) | en_US |
dc.relation.ispartofseries | Proceedings of the Malaysian Technical Universities Conference on Engineering and Technology (MUCET) 2012 | en_US |
dc.subject | EEG | en_US |
dc.subject | Input impedance | en_US |
dc.subject | CMRR | en_US |
dc.subject | Active filter | en_US |
dc.subject | EEG amplifier | en_US |
dc.title | Application-specific multichannel EEG data acquisition system for portable biomedical application | en_US |
dc.type | Working Paper | en_US |
dc.contributor.url | paul@unimap.edu.my | en_US |
Appears in Collections: | Conference Papers Abdul Hamid Adom, Prof. Dr. Paulraj Murugesa Pandiyan, Assoc. Prof. Dr. |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
EEE 12.pdf | Access is limited to UniMAP community | 723.11 kB | Adobe PDF | View/Open |
Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.