Please use this identifier to cite or link to this item:
http://dspace.unimap.edu.my:80/xmlui/handle/123456789/2544
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ismail, Daut | - |
dc.contributor.author | Syafruddin, Hasan | - |
dc.contributor.author | Rosnazri, Ali | - |
dc.contributor.author | Samila, Mat Zali | - |
dc.contributor.author | Haziah, Abd Hamid | - |
dc.date.accessioned | 2008-10-22T07:12:30Z | - |
dc.date.available | 2008-10-22T07:12:30Z | - |
dc.date.issued | 2006 | - |
dc.identifier.citation | American Journal of Applied Sciences, vol. 3 (12), 2006, pages 2131-2133. | en_US |
dc.identifier.issn | 1546-9239 | - |
dc.identifier.uri | http://dspace.unimap.edu.my/123456789/2544 | - |
dc.description | Link to publisher's homepage at http://scipub.org/scipub/index.php | en_US |
dc.description.abstract | An important consideration when evaluating the impact of harmonics is their effect on power system component and loads. Sinusoidalare major components in power systems. The increased losses due to harmonic distortion can cause excessive losses and hence abnormal temperature rise. The measurement of iron losses and copper losses of single-phase transformers is important in particular for transformers feeding nonlinear loads. In computing of transformer losses, it is assumed that source voltage is sinusoidal and load impedance is linear. This study presents the effects of harmonic distortion of load current and voltage on single-phase transformer losses utilizing the on-line measurements (monitoring) method of the primary side. The transformer is loaded with an SCR speed controller that consists of a single-phase full-bridge rectifier, SCR and a resistant load to generate various total harmonic current and voltage distortions (THDi and THDv) conditions. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Science Publications | en_US |
dc.subject | Harmonic | en_US |
dc.subject | Sinusoidal source | en_US |
dc.subject | Nonlinear load | en_US |
dc.subject | Total harmonic distortion (THD) | en_US |
dc.subject | Electro-acoustics | en_US |
dc.subject | Electric engineering | en_US |
dc.subject | Electric tranformers | en_US |
dc.title | The effects of harmonic components on transformer losses of sinusoidal source supplying non-linear loads | en_US |
dc.type | Article | en_US |
dc.identifier.url | http://scipub.org/scipub/index.php | en_US |
Appears in Collections: | School of Electrical Systems Engineering (Articles) Ismail Daut, Prof. Dr. |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Effects of Harmonic Components on Transformer Losses.pdf | 112.98 kB | Adobe PDF | View/Open |
Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.