Please use this identifier to cite or link to this item:
http://dspace.unimap.edu.my:80/xmlui/handle/123456789/24440| Title: | The comparative study between R-22 and R-410A as refrigerant in air conditioning applications |
| Authors: | Soon, Kuok Hau Salsuwanda Selamat |
| Keywords: | Ozone (O3) Air conditioning system Refrigerant R-22 Refrigerant R-410A |
| Issue Date: | May-2012 |
| Publisher: | Universiti Malaysia Perlis (UniMAP) |
| Abstract: | Since the ozone hole was discovered in the late 1970s, a lot researches had been carried out to determine the main contribution to this phenomena. One of the main contributions is the refrigerant R-22. Previous researches showed that R-22 disintegrate the ozone molecules when chlorine atom reacted with ozone molecules, resulted in ozone depletion. In order to reduce the ozone depletion, R-22 was scheduled to be phased out and alternatives were determined to replace R-22. This study reports the thermal characteristic and environmental attributes of R-22 and R-410A refrigerants. The experiment was conducted in a test room in the School of Environmental Engineering, University Malaysia Perlis. The performances of both refrigerants were experimentally determined. The experimental data were taken every 15 minutes in 12 hours a day from 8 February to 15 March 2012. The average coefficient of performance (COP) was determined using the measured temperature of the cooled space and ambient temperature. Average COP for the R-22 and R-410A refrigerant were 4.8 and 6.3 respectively. The average power consumption for R-22 refrigerant and R-410A were 6.9 kilowatt and 5.6 kilowatt respectively. The experiment results indicate that R-410A refrigerant is economically preferable, more environmental friendly and has a better performance therefore it is an alternative solution for replacing the obsolete R-22 refrigerant. |
| Description: | Access is limited to UniMAP community. |
| URI: | http://dspace.unimap.edu.my/123456789/24440 |
| Appears in Collections: | School of Environmental Engineering (FYP) |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Reference and appendix.pdf | 208.21 kB | Adobe PDF | View/Open | |
| Conclusion.pdf | 123.7 kB | Adobe PDF | View/Open | |
| Results and discussion.pdf | 185.64 kB | Adobe PDF | View/Open | |
| Methodology.pdf | 188.25 kB | Adobe PDF | View/Open | |
| Literature review.pdf | 205.3 kB | Adobe PDF | View/Open | |
| Introduction.pdf | 182.04 kB | Adobe PDF | View/Open | |
| Abstract, Acknowledgement.pdf | 453.47 kB | Adobe PDF | View/Open |
Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.