Please use this identifier to cite or link to this item: http://dspace.unimap.edu.my:80/xmlui/handle/123456789/24135
Title: Enhancement of above ceiling cpace for utilization: single storey terrace house in Malaysia
Authors: Azuan Aziz, Awang
Ir Muhammad Arkam Che Munaaim
Keywords: Attic construction
Attic ventilation rate
Attic roof
Attic dormers
Rafter
Wood
Plywood
Issue Date: May-2012
Publisher: Universiti Malaysia Perlis (UniMAP)
Abstract: Use of ceiling space or attic, has a lot of increase in foreign countries but not in Malaysia, probably because the weather in Malaysia is equatorial climates where rain and warm throughout the year. This research made is to develop a method by using timber component and recommend roof-ceiling space for general utilization with minimal cost for single storey house in Malaysia. To determine whether the use of ceiling space can be increased or not, the questionnaires were distributed and there were 64 respondents who answered the question where the respondents obtained from six of the different resident areas around Perlis. There are 62 out of 64 respondents agreed that if the ceiling space usage can be improved in Malaysia. To determine the estimated cost of attic construction, the price of materials relating to the attic is collected and the cost of materials is calculated based on current prices obtained from the hardware around Perlis. Structure truss to be designed and determined whether it is stable or unstable before the calculation of the cost is made to avoid collapse or fail. Through the calculations made, the total cost of materials for the construction of the attic is RM 18774.7 while the total cost of materials for the construction of the normal roof is the RM 6386.15, The attic space is obtained by 13.38 m² where the volume of attic is 97.41 m³ where the length of attic is 4.46 m, height is 3 m and the width of attic is 7.28 m. Can be concluded that the total cost of the attic construction is the reasonable cost in Malaysia.
Description: Access is limited to UniMAP community.
URI: http://dspace.unimap.edu.my/123456789/24135
Appears in Collections:School of Environmental Engineering (FYP)

Files in This Item:
File Description SizeFormat 
Reference and appendix.pdf152.28 kBAdobe PDFView/Open
Conclusion.pdf148.17 kBAdobe PDFView/Open
Results and discussion.pdf935.75 kBAdobe PDFView/Open
Methodology.pdf168.52 kBAdobe PDFView/Open
Literature review.pdf277.69 kBAdobe PDFView/Open
Introduction.pdf159.03 kBAdobe PDFView/Open
Abstract, Acknowledgement.pdf131.81 kBAdobe PDFView/Open


Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.