dc.description.abstractAnalysis of a structure is very important in term of measuring the structure stability. When a load is applied to the structure, it will result deformation of the entire structure. Furthermore, if the deformation of the structure is too large, the structure become unstable and may cause collapse to the structure. But one of the common methods to predict the deformation of the structure is by using stiffness method. Unfortunately, most of the analysis of the structures done by engineers using stiffness method is mainly based on first-order elastic analysis only. By only considering first-order elastic analysis; the calculation of the deformation of the structure is not really accurate especially for structure with low stiffness because failure of structure when seismic occur This study was conducted to determine the deformation of a frame structure more accurate by considering non-linear effect (second-order elastic analysis) and compare the result with linear effect ( first-order-elastic analysis) in term of the structural element of the RC frame and overstrength . The non –linear effect ( second –order elastic analysis ) will conducted via manual calculation by using eurocode 2 and eurocode 8. A part from manual calculation computer software such as cumbia , excel , matlab and SAP200 was used to determine the maximum shear strength, moment and axial load applicable for a structure to maximize the stability and strength of the structure. The result of this study shown that there are different in the structral element designed using second order analaysis compared to first order analysis. Apart from that the overstrength of RC frame shown different when different method applied where for EC2 the overstrength value is 1.19 and for frame designed using EC8 the value of overstrength is 1.20en_US
dc.language.isoenen_US
dc.publisherUniversiti Malaysia Perlis (UniMAP)en_US
dc.subjectEarthquakeen_US
dc.subjectDuctility classen_US
dc.subjectGravity loaden_US
dc.subjectSeismic loaden_US
dc.subjectEurocodeen_US
dc.titleComparison between gravity load and seismic load designed irregular buildingen_US
dc.typeLearning Objecten_US
dc.contributor.advisorMohd Zulham Affandi Bin Mohd Zahiden_US
dc.publisher.departmentSchool of Environmental Engineeringen_US
Appears in Collections:School of Environmental Engineering (FYP)

Files in This Item:
File Description SizeFormat 
Reference and appendix.pdf280.55 kBAdobe PDFView/Open
Conclusion.pdf113.92 kBAdobe PDFView/Open
Results and discussion.pdf280.96 kBAdobe PDFView/Open
Methodology.pdf179.34 kBAdobe PDFView/Open
Literature Review.pdf341.1 kBAdobe PDFView/Open
Introduction.pdf122.7 kBAdobe PDFView/Open
Abstract, Acknowledgement.pdf337.21 kBAdobe PDFView/Open


Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.