dc.descriptionInternational Postgraduate Conference On Engineering (IPCE 2010), 16th - 17th October 2010 organized by Centre for Graduate Studies, Universiti Malaysia Perlis (UniMAP) at School of Mechatronic Engineering, Pauh Putra Campus, Perlis, Malaysia.en_US
dc.description.abstractThis paper describes the result of measurement of inplane flux distribution on 100kVA 3phase distribution transformer assembled with the mix 60o- 45o T-joint and mitred lap corner joint with stagger yoke of 10mm. The measurement involves the fundamental, third and fifth harmonic of the easy and hard direction of flux density at each location measurement. The flux distributions have been measured using no load test by arrays of search coil in M5 (CGO) grades material of transformer core laminations. The localised flux density at the outer 60o-45o T-joint is 1.4T and rises to be 1.68T at the inner edges of 60o-45o T-joint when the transformer core energized 1.5 T 50Hz. Harmonic occurs mostly in the Tjoint where local regions are saturated and the flux deviates from the rolling direction.A small amount of flux deviation from the rolling direction occurs at the overlap, but no rotational flux is present in the joint.en_US
dc.language.isoenen_US
dc.publisherUniversiti Malaysia Perlis (UniMAP)en_US
dc.relation.ispartofseriesProceedings of the International Postgraduate Conference on Engineering (IPCE 2010)en_US
dc.subjectDistribution transformeren_US
dc.subjectIn-plane fluxen_US
dc.subjectThird harmonicen_US
dc.titleIn-plane flux distribution in the mix 60o- 45o T-joint of three phase transformer coreen_US
dc.typeWorking Paperen_US
dc.publisher.departmentCentre for Graduate Studiesen_US
dc.contributor.urldina@unimap.edu.myen_US
dc.contributor.urlismail.daut@unimap.edu.myen_US
Appears in Collections:Conference Papers
Ismail Daut, Prof. Dr.

Files in This Item:
File Description SizeFormat 
C02 Dina M.M. Ahmad.pdf568.27 kBAdobe PDFView/Open


Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.