Please use this identifier to cite or link to this item:
http://dspace.unimap.edu.my:80/xmlui/handle/123456789/21224
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Risnidar Chan Bahaudin, Ir. | - |
dc.contributor.author | Ismail, Daut, Prof. Dr. | - |
dc.contributor.author | Syafruddin, Hassan | - |
dc.contributor.author | M. I., Yussof | - |
dc.contributor.author | Rosnazri, Ali | - |
dc.contributor.author | Dina Maizana, Maiz Ahmad | - |
dc.contributor.author | Indra, Nisja | - |
dc.contributor.author | Masykur | - |
dc.date.accessioned | 2012-10-05T04:05:00Z | - |
dc.date.available | 2012-10-05T04:05:00Z | - |
dc.date.issued | 2010-10-16 | - |
dc.identifier.isbn | 978-967-5760-03-7 | - |
dc.identifier.uri | http://dspace.unimap.edu.my/123456789/21224 | - |
dc.description | International Postgraduate Conference On Engineering (IPCE 2010), 16th - 17th October 2010 organized by Centre for Graduate Studies, Universiti Malaysia Perlis (UniMAP) at School of Mechatronic Engineering, Pauh Putra Campus, Arau, Perlis, Malaysia. | en_US |
dc.description.abstract | This paper discussed about power factor on harmonic effect due to types of voltage source. Usually, the voltage source is sinusoidal. But in actually, the condition of the load is has voltage sources through the elements where the output voltage of element as input to load is did not pure sinusoidal, for example at PCC between transformer and linear load and nonlinear load. The research has done with Schhafner Power Quality Analyzer. The research was focused to power factor (p.f.), THD, and harmonic energy losses cost from measurement where load is Induction motor and ASD. As voltage source in this research are sine wave and combinations of 3rd, 5th and 7th harmonic order like harmonic 313, and harmonic 357. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Universiti Malaysia Perlis (UniMAP) | en_US |
dc.relation.ispartofseries | Proceedings of the International Postgraduate Conference on Engineering (IPCE 2010) | en_US |
dc.subject | Type of voltage source | en_US |
dc.subject | Power factor | en_US |
dc.subject | Energy losses cost | en_US |
dc.subject | Harmonic | en_US |
dc.subject | Total Harmonic Distortion (THD) | en_US |
dc.title | Investigation of power factor on harmonic effect due to types of voltage source | en_US |
dc.type | Working Paper | en_US |
dc.publisher.department | Centre for Graduate Studies | en_US |
dc.contributor.url | risnidar@unimap.edu.my | en_US |
Appears in Collections: | Conference Papers Ismail Daut, Prof. Dr. |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
C14 Risnidar C. B.pdf | 870.19 kB | Adobe PDF | View/Open |
Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.