Please use this identifier to cite or link to this item: http://dspace.unimap.edu.my:80/xmlui/handle/123456789/20833
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMohd Noor Nassriq, Safie-
dc.date.accessioned2012-09-05T11:45:15Z-
dc.date.available2012-09-05T11:45:15Z-
dc.date.issued2009-04-
dc.identifier.urihttp://dspace.unimap.edu.my/123456789/20833-
dc.descriptionAccess is limited to UniMAP community.en_US
dc.description.abstractSince the introduction of endovascular techniques in the early 1990s for the treatment of abdominal aortic aneurysms (AAAs), the insertion of a stent-graft (SG) into the affected artery segment has been greatly successful for a certain group of AAA patients and is continuously evolving. However, although minimally invasive aneurysm repair is very attractive, post-operative complications may occur. The purpose of this paper is studying the effectiveness of stent geometry in terms of protecting the weak wall of an aneurysm sack from the impact of blood flow. Two dimensional model of a simplified aneurysm model was constructed with and without SG which have same parameter by using Solidworks2005. Blood flow was simulated across the aneurysm sack using (Engineering Fluid Dynamics) EFD. Lab7 software. The results showed a slight increase in pressure within the aneurysm region under simulated blood flow. When SG was introduced, the pressure at the aneurysm site was reduced. This study confirms the effectiveness of the aneurysm repair in terms of protecting the blood vessel from a possible rupture.en_US
dc.language.isoenen_US
dc.publisherUniversiti Malaysia Perlisen_US
dc.subjectEndovascular techniquesen_US
dc.subjectAbdominal Aortic Aneurysms (AAA)en_US
dc.subjectStent-graft (SG)en_US
dc.subjectAneurysmsen_US
dc.subjectArteryen_US
dc.subjectBlood vesselen_US
dc.titleCharacterization of the stent-grafts performance in abdominal aortic aneurysmsen_US
dc.typeLearning Objecten_US
dc.contributor.advisorNur Farahiyah Mohammaden_US
dc.publisher.departmentSchool of Mechatronic Engineeringen_US
Appears in Collections:School of Mechatronic Engineering (FYP)

Files in This Item:
File Description SizeFormat 
References and appendix.pdf122.84 kBAdobe PDFView/Open
Conclusion.pdf131.83 kBAdobe PDFView/Open
Results and discussion.pdf255.9 kBAdobe PDFView/Open
Methodology.pdf379.31 kBAdobe PDFView/Open
Literature review.pdf622.16 kBAdobe PDFView/Open
Introduction.pdf148.65 kBAdobe PDFView/Open
Abstract, Acknowledgement.pdf400.55 kBAdobe PDFView/Open


Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.