Please use this identifier to cite or link to this item: http://dspace.unimap.edu.my:80/xmlui/handle/123456789/20565
Full metadata record
DC FieldValueLanguage
dc.contributor.authorNormahira, Mamat @Mohamad Nor-
dc.contributor.authorNoor Azuan, Abu Osman-
dc.contributor.authorAtalullah, Oshkour-
dc.date.accessioned2012-08-03T05:29:04Z-
dc.date.available2012-08-03T05:29:04Z-
dc.date.issued2012-02-27-
dc.identifier.citationp. 38-43en_US
dc.identifier.isbn978-1-4577-1990-5-
dc.identifier.urihttp://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=06178951-
dc.identifier.urihttp://dspace.unimap.edu.my/123456789/20565-
dc.descriptionLink to publisher's homepage at http://ieeexplore.ieee.org/en_US
dc.description.abstractIn this study, the mechanical responses for the knee joint model in various degrees of flexion and loadings during gait are investigated. Three gait phases consisting of heel strike (HS) (5.5°), single limb stance (SLS) (15.5°), and toe-off (TO) (4.5°) are considered to represent the gait cycle while simulated loading conditions applied for each phase are 2.25 times body weight (BW), 1.85 times BW, and 3.5 times BW, respectively, where the BW is 495 N. The knee images are imported from a computerized tomography (CT) scan to Mimics version 13.1 software for smoothing and constructing to the three-dimensional (3D) model of the tibio-femoral (TF) joint. Finite element analysis (FEA) using the ABAQUS v.6.7 software was performed to simulate the biomechanical patterns of the tibiofemoral (TF) joint. The knee joint is modeled with femur condyles, tibia plateau, and menisci attachment. The contact pressure toward these 3 components is investigated at each medial and lateral compartment of the joint parts. The simulating results are verified and compared with well-known results in the literatures, which showed that contact pressure behaved much greater on the medial compartments than on the lateral compartments throughout the phases. Meanwhile, it was found that the peak contact pressure occurred during TO.en_US
dc.language.isoenen_US
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)en_US
dc.relation.ispartofseriesProceedings of the International Conference on Biomedical Engineering (ICoBE 2012)en_US
dc.subjectTibiofemoralen_US
dc.subjectFemuren_US
dc.subjectTibiaen_US
dc.subjectMeniscien_US
dc.subjectMedial Compartmenten_US
dc.titleNumerical measurement of contact pressure in the tibiofemoral joint during gaiten_US
dc.typeWorking Paperen_US
dc.contributor.urlnormahira@unimap.edu.myen_US
Appears in Collections:Conference Papers
Normahira Mamat @ Mohamad Nor, Dr.

Files in This Item:
File Description SizeFormat 
1B4.pdfAccess is limited to UniMAP community1.02 MBAdobe PDFView/Open


Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.