Please use this identifier to cite or link to this item: http://dspace.unimap.edu.my:80/xmlui/handle/123456789/20503
Full metadata record
DC FieldValueLanguage
dc.contributor.authorM. Shahiri-Tabarestani-
dc.contributor.authorB. A. Ganji-
dc.contributor.authorR. Sabbaghi-Nadooshan-
dc.date.accessioned2012-07-19T14:41:13Z-
dc.date.available2012-07-19T14:41:13Z-
dc.date.issued2012-02-27-
dc.identifier.urihttp://dspace.unimap.edu.my/123456789/20503-
dc.descriptionInternational Conference on Man Machine Systems (ICoMMS 2012) organized by School of Mechatronic Engineering, co-organized by The Institute of Engineer, Malaysia (IEM) and Society of Engineering Education Malaysia, 27th - 28th February 2012 at Bayview Beach Resort, Penang, Malaysia.en_US
dc.description.abstractTo design mechanical pressure sensors, analysis of the deflection behavior of diaphragms is necessary. This paper describes effective factors on diaphragm's deflection and mechanical sensitivity of an Intraocular capacitive pressure sensor. Intraocular pressure sensors are important in detection and treatment of a fatal disease attributed to glaucoma. These pressure sensors have been designed to measure pressures in the range of 0 to 60 mmHg. This type of sensors operate by deformation of movable membrane for IOP diagnosis. So deflection of the diaphragm is a main factor for better performance of these pressure sensors. The principle of the paper is to Evaluate effective factors on sensor diaphragm and compare the results with the simulation using FEA method for a square diaphragm deflection. Generally, analysis of diaphragm behaviors are useful as they provide the designers better understanding and supplemental guidance.en_US
dc.language.isoenen_US
dc.publisherUniversiti Malaysia Perlis (UniMAP)en_US
dc.relation.ispartofseriesProceedings of the International Conference on Man-Machine Systems (ICoMMS 2012)en_US
dc.subjectDeflectionen_US
dc.subjectMechanical sensitivityen_US
dc.subjectIntraocular pressureen_US
dc.subjectSensitivityen_US
dc.titleEvaluation of effective factors on Diaphragm's Deflection and mechanical sensitivity of an intraocular capacitive pressure sensoren_US
dc.typeWorking Paperen_US
dc.publisher.departmentSchool of Mechatronic Engineeringen_US
dc.contributor.urlcmos_1945@yahoo.comen_US
dc.contributor.urlbaganji@nit.ac.iren_US
dc.contributor.urlR_sabbaghi@iauctb.ac.iren_US
Appears in Collections:Conference Papers

Files in This Item:
File Description SizeFormat 
132-96173_Evaluation of Effective Factors on Diaphragm's Deflection and Mechanical Sensitivity of an Intraocular Capaciti~1.pdfAccess is limited to UniMAP community324.21 kBAdobe PDFView/Open


Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.