Please use this identifier to cite or link to this item:
http://dspace.unimap.edu.my:80/xmlui/handle/123456789/19196
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Husna, A. W. N. | - |
dc.contributor.author | Siti Fatimah, Siraj, Prof. Madya. Dr. | - |
dc.contributor.author | Mahathir, H. Mat | - |
dc.date.accessioned | 2012-05-13T14:40:49Z | - |
dc.date.available | 2012-05-13T14:40:49Z | - |
dc.date.issued | 2011-09-20 | - |
dc.identifier.citation | p. 394-398 | en_US |
dc.identifier.isbn | 978-076954562-2 | - |
dc.identifier.uri | http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6076392 | - |
dc.identifier.uri | http://dspace.unimap.edu.my/123456789/19196 | - |
dc.description | Link to publisher's homepage at http://ieeexplore.ieee.org/ | en_US |
dc.description.abstract | The effect of load variations on the stability of the open-loop DC-DC boost converter is investigated in this paper. Mathematical model of boost converter is derived using state-space averaging technique and perturbation technique presented in this paper to linearize the small AC components. The calculations have been done to ensure the converter is operates in continuous conduction mode (CCM). The open-loop system of boost converter is developed using MATLAB/Simulink software along with the simulation results. The changing of load parameter has been studied so that the stable design of boost converter can be carried out by following a systematic procedure. From the simulation results, it can be shown that load variation gives significant effect on the transient response of the converter. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Institute of Electrical and Electronics Engineers (IEEE) | en_US |
dc.relation.ispartofseries | Proceedings of the 3rd International Conference on Computational Intelligence, Modelling and Simulation (CIMSim) 2011 | en_US |
dc.subject | Continuous Conduction Mode (CCM) | en_US |
dc.subject | DC-DC boost converter | en_US |
dc.subject | MATLAB / Simulink | en_US |
dc.subject | Perturbation technique | en_US |
dc.subject | State-space averaging technique | en_US |
dc.title | Effect of load variations in DC-DC converter | en_US |
dc.type | Working Paper | en_US |
dc.contributor.url | nurulhusna.awb@gmail.com | en_US |
dc.contributor.url | fatimahsiraj@unimap.edu.my | en_US |
dc.contributor.url | hafizuddin.mat@gmail.com | en_US |
Appears in Collections: | Conference Papers |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Effect of load variations in DC-DC converter.pdf | 52.41 kB | Adobe PDF | View/Open |
Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.