Please use this identifier to cite or link to this item: http://dspace.unimap.edu.my:80/xmlui/handle/123456789/15086
Title: Parameter determination of 0.5 hp induction motor based on load factor test - A case study
Authors: Ismail, Daut, Prof. Dr.
Gomesh Nair, Shasidharan
Muhammad Irwanto
Yanawati, Y.
Nor Shafiqin, S.
Mohd Irwan, Yusoff
Keywords: Efficiency
Energy consumption
Load factor
Mechanical output power
Motor losses
Issue Date: 21-Jun-2011
Publisher: Institute of Electrical and Electronics Engineers (IEEE)
Citation: p. 477-480
Series/Report no.: Proceedings of the 1st International Conference on Electrical, Control and Computer Engineering 2011 (InECCE 2011)
Abstract: The load can influence the efficiency of the induction motor. Even if the load has higher or less load factor, it can reduce the efficiency of an induction motor by several percentage. By knowing this, it is important that an induction motor be loaded with an appropriate or load factor of 100%. In this paper, the experiment is conducted to prove that efficiency decreases when the 0.5 hp induction motor's is interfaced under low load factor condition and in this case a 65% load factor. The induction motor is interfaced with a DC generator and a variable resistance as load. In order to determined the efficiency and the mechanical output power of the induction motor, the voltage of the induction motor is varied from 0-415 volt and the appropriate data is taken. This is then analysis and several calculation formulas are used to determine the motor's parameters. After that the losses are segregated and from this we can compare the efficiency values in which it shows low efficiency of 66.62% based on output/input method and 66.34% by using the losses formula. This proofs that at low load factor the efficiency of the induction motor reduces.
Description: Link to publisher's homepage at http://ieeexplore.ieee.org/
URI: http://ieeexplore.ieee.org/xpl/freeabs_all.jsp?arnumber=5953929
http://dspace.unimap.edu.my/123456789/15086
ISBN: 978-1-6128-4228-8
Appears in Collections:Conference Papers
Ismail Daut, Prof. Dr.
Gomesh Nair Shasidharan, Dr.
Mohd Irwan Yusoff, Dr.

Files in This Item:
File Description SizeFormat 
Parameter determination of 0.5 hp induction motor based onload factor test - A case study.pdf67.53 kBAdobe PDFView/Open


Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.