Please use this identifier to cite or link to this item:
http://dspace.unimap.edu.my:80/xmlui/handle/123456789/10451
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Mohd. Yusof, Baharuddin | - |
dc.contributor.author | Mohammed Rafiq, Abdul Kadir | - |
dc.date.accessioned | 2011-01-10T04:05:31Z | - |
dc.date.available | 2011-01-10T04:05:31Z | - |
dc.date.issued | 2010-08-01 | - |
dc.identifier.citation | Vol. 31, p. 605-607 | en_US |
dc.identifier.isbn | 978-3-5407-9038-9 | - |
dc.identifier.issn | 1680-0737 | - |
dc.identifier.uri | http://www.springerlink.com/content/v82mqw0v36060461/fulltext.pdf | - |
dc.identifier.uri | http://dspace.unimap.edu.my/123456789/10451 | - |
dc.description | Link to publisher's homepage at www.ifmbe.org/ | en_US |
dc.description.abstract | Major problem associated with the cementless design is the lack of stability. Several design features were introduced to provide the much needed stability for bone integration. These include fins, fiber mesh, beads, indentations and collars. The use of collar has been a subject of controversy with mixed reports of clinical outcomes. In this study, the effectiveness of collar in terms of providing stability was analysed using finite element method. Three dimensional model of a human femur was constructed from CT dataset and hip arthroplasty was simulated. With an applied joint contact load simulating physiological gait, micromotion of the implant relative to the bone was calculated via an experimentally validated algorithm. Results showed that collar did not improve stability of the whole stem but only around the medial calcar region. | en_US |
dc.language.iso | en | en_US |
dc.publisher | International Federation for Medical and Biological Engineering | en_US |
dc.relation.ispartofseries | Proceedings of the International Federation for Medical and Biological Engineering (IFMBE) 2010 | en_US |
dc.subject | Micromotion | en_US |
dc.subject | Stability | en_US |
dc.subject | Total Hip Arthroplasty | en_US |
dc.title | Finite element study on the micromotion of cementless total hip arthroplasty | en_US |
dc.type | Working Paper | en_US |
dc.contributor.url | myusof@unimap.edu.my | en_US |
Appears in Collections: | Conference Papers |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Finite element study on the micromotion of cementless total hip arthroplasty.pdf | 26.49 kB | Adobe PDF | View/Open |
Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.