Please use this identifier to cite or link to this item:
http://dspace.unimap.edu.my:80/xmlui/handle/123456789/10407
Title: | Effect of solution treatment on Mg galvanic anodes in CaSO4 – MG(OH)2 aqueous solution |
Authors: | A. M. H., Firdaus Shaiful Rizam, Shamsudin Shamsul Baharin, Jamaludin, Prof. Dr. M. N., Derman Mohd Fitri, Mohamad Wahid C. I., Mahdi rizam@unimap.edu.my |
Keywords: | Malaysian International NDT Conference and Exhibition (MINDTCE) 2009 Aqueous solution Heat treatment Magnesium Sacrificial anode Corrosion rate Electrochemical |
Issue Date: | 20-Jul-2009 |
Publisher: | PETRONAS |
Series/Report no.: | Proceedings of the Malaysian International NDT Conference and Exhibition 2009 (MINDTCE 2009) |
Abstract: | The effect of heat treatment on the Mg anode was investigated in CaSO4-Mg(OH)2 aqueous solution. The Mg sample was solutionised at 150oC, Pure and untreated Mg anode were also studied as a reference. Eoc and Tafel corrosion rate was determined by mean of potentiostat. It was found that solution treatment was significantly affecting the performance of Mg anode where it Eoc was electronegatively increases to -1.6404VSCE and the Tafel corrosion rate reduces to 12.23 mpy. |
Description: | Malaysia International NDT “Non Destructive Testing” Conference and Exhibition ‘09 (MINDTCE ’09), 20th - 21st of July 2009 was held in Kuala Lumpur. Organized by PETRONAS, ASCOPE GAS Centre, MSNT, SIRIM and Nuclear Malaysia. |
URI: | http://dspace.unimap.edu.my/123456789/10407 |
Appears in Collections: | Conference Papers Mohd Nazree Derman, Assoc. Prof. Dr. Shamsul Baharin Jamaludin, Prof. Dr. |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Effect of Solution Treatment on Mg Galvanic Anodes in CaSO4.pdf | Access is limited to UniMAP community | 173.56 kB | Adobe PDF | View/Open |
Items in UniMAP Library Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.