Search
Now showing items 1-5 of 5
Metallurgical failure analysis of a closed recirculation system water cooling pipe
(Trans Tech Publications, 2013)
Catastrophic failure is often associated with a large temperature rise. This situation may lead to a drastic deterioration in material strength where a cooling system is important for a smooth system plant operation to ...
Potentiodynamic polarization of Mg-0.22ca alloys containing minor element of Aluminium
(Universiti Malaysia Perlis, 2009-12-01)
Mg alloys played a significant role in replacing the existing sacrificial anodes. To maintain the negative potential and its capability in preventing corrosion, Ca and Al was added as alloying elements. Polarization curves ...
Failure analysis on a ruptured petrochemical pipe
(Carl Hanser Verlag, 2010-03-16)
The failure took place on a welded elbow pipe
which exhibited a catastrophic transverse rupture.
The failure was located on the welding HAZ
region, parallel to the welding path. Branching
cracks were detected at the ...
Long term overheating failure of a closed recirculation system water cooling pipe
(SIRIM, 2010-11-22)
Catastrophic failure is often associated with a large temperature rise. This situation may lead to a drastic
deterioration in material strength where a cooling system is important for a smooth system plant operation
to ...
Development of a Lid Sealed furnace for the production of Magnesium alloys
(Universiti Kebangsaan Malaysia (UKM), 2008-12-03)
An atmosphere-controlled furnace was designed for the casting process of highly reactive Mg metal and its alloys. Instead of open crucible furnace, the melting process was done under controlled atmosphere which contained ...