    Development of mechanical prosthetic hand system for BCI application

    Thumbnail
    View/Open
    Development of mechanical prosthetic hand system for BCI application-abstract.pdf (58.68Kb)
    Date
    2008
    Author
    Noor Azuan, Abu Osman, Professor Ir. Dr.
    Shuhaida, Yahud, Dr.
    Sing, Yau Goh
    Metadata
    Show full item record
    Abstract
    The study is to develop a prosthetic hand that can be controlled by Brain-Computer Interface (BCI). The proposed prosthetic hand consists of palm and 5 fingers. The hand was designed to perform the 4 predetermined essential tasks in BCI applications; cylindrical grasp, key pinch, pulp to pulp pinch and tripod pinch. The phalanges of the finger was modeled as three link open chain joined at the metacarpal joint (MCP), proximal joint (PIP) and distal joint (DIP). Each segment denote as phalanx was made from two parallel aluminum plates and connected to the other segment using a bolted spacer acting as hinge joint. Length of each segment was made such that it will form an equiangular motion path during trajectory. Each joint is actuated by its individual actuator. Two mechanisms were proposed in this study. The first mechanism is the tendon drive; used terelyne string to pull each segment to flexion. The second mechanism is a spring return; a stored resistive force in torsion spring will kick the segment to its initial position. The hand was equipped with potentiometers and pressure sensors for control purposes. The prototype was tested with BCI system, in order to meet its initial objective and additional tests were carried out to evaluate its performance. An experiment to test the performance of the prosthetic hand was carried out successfully. Strength of each tendon was measured using a proof ring method and motion images were captured using video camera and analyzed using Peak Motus Performance 2000 Motion Analysis software.
    URI
    http://connection.ebscohost.com/c/articles/33248005
    http://dspace.unimap.edu.my:80/dspace/handle/123456789/34875
    Collections
    • Shuhaida Yahud, Assoc. Prof. Dr. [7]

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback
     

     

    Browse

    All of UniMAP Library Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Atmire NV

    Perpustakaan Tuanku Syed Faizuddin Putra (PTSFP) | Send Feedback