Now showing items 1-9 of 9

    • Edge detection algorithm for enhancement of linear back projection tomographic images 

      Muhammad Jaysuman, Pusppanathan; Mahdi Faramarzi; Fazlul Rahman, Mohd Yunus; Nor Muzakkir, Nor Ayob; Ruzairi, Abdul Rahim, Prof. Dr.; Fatin Aliah, Phang Abdullah, Dr.; Usman Ullah, Sheikh, Dr.; Loew,  Pei Ling, Dr.; Khairul Hamimah, Abas; Mohd Hafiz, Fazalul Rahiman, Dr.; Shafishuhaza, Sahlan (Penerbit UTM Press, 2014)
      Process tomography (PT) is a leading technique for multiphase flow measurement and flow monitoring systems in various fields. PT has the advantage of interpreting acquired measurement data and transforming it into visual ...
    • The hardware design technique for ultrasonic process tomography system 

      Mohd Hafiz, Fazalul Rahiman, Dr.; Ruzairi, Abdul Rahim, Prof. Dr.; Herlina, Abdul Rahim, Dr.; Nor Muzakkir, Nor Ayob (International Frequency Sensor Association Publishing (IFSA), 2012-06)
      This paper describes a work carried out to design and development an ultrasonic process tomography system. The hardware design technique is of interest of this paper. A number of 32-ultrasonic transducers have been ...
    • Optical tomography system based on charge-coupled device linear image sensors: Particle size measurement 

      Idroas, M.; Ruzairi, Abdul Rahim; Mohd Hafiz, Fazalul Rahiman; Ibrahim, M. N. (Elsevier B.V, 2011-08)
      This paper discussed an optical tomography system based on charge-coupled device (CCD) linear image sensors. The developed system consists of a lighting system, a measurement section and a data acquisition system. Four CCD ...
    • Optical tomography system based on charge-coupled device linear image sensors: Particle size measurement 

      Mariani, Idroas; Ruzairi, Abdul Rahim; Mohd Hafiz, Fazalul Rahiman; M. N., Ibrahim (Elsevier B.V., 2011-08)
      This paper discussed an optical tomography system based on charge-coupled device (CCD) linear image sensors. The developed system consists of a lighting system, a measurement section and a data acquisition system. Four CCD ...
    • An optical tomography system using a digital signal processor 

      Ruzairi, Abdul Rahim; Chiam, Kok Thiam; Mohd Hafiz, Fazalul Rahiman (Molecular Diversity Preservation International (MDPI), 2008-03)
      The use of a personal computer together with a Data Acquisition System (DAQ) as the processing tool in optical tomography systems has been the norm ever since the beginning of process tomography. However, advancements in ...
    • Optical tomography system: Application of Charge Coupled Device (CCD) for solid and transparent objects detection 

      Juliza, Jamaludin; Ruzairi, Abdul Rahim; Herlina, Abdul Rahim; Mohd Hafiz, Fazalul Rahiman; Siti Zarina, Mohd Muji; Mohd Fahjumi, Jumaah; Naizatul Shima, Mohd Fadzil; Chan, Kok San; Green, R.G. (Penerbit UTM Press, 2016)
      This research presents an application of Charge Coupled Device (CCD) linear sensor and laser diode in an optical tomography system. These optoelectronic sensors are believed to detect solid objects rather than transparent ...
    • Optical tomography: A review on sensor array, projection arrangement and image reconstruction algorithm 

      Siti Zarina, Mohd. Muji; Ruzairi, Abdul Rahim; Mohd Hafiz, Fazalul Rahiman; Shafishuhaza, Sahlan; Mohd Fadzli, Abdul Shaib; Muhammad, Jaysuman; Elmy Johana, Mohamad (Kyushu Tokai University, 2011-07)
      This paper reviews previous research on sensor arrays, projection arrangements and image reconstruction algorithms of optical tomography for industrial processes. These include the review of sensor selection and projection ...
    • A study on forward and inverse problems for an ultrasonic tomography 

      Mohd Hafiz, Fazalul Rahiman, Dr.; Ruzairi, Abdul Rahim, Prof. Dr.; Herlina, Abdul Rahim, Dr.; Zulkarnay, Zakaria; Muhammad Jaysuman, Pusppanathan (Penerbit UTM Press, 2014)
      This paper studies the solution for inverse and forward problems for an ultrasonic tomography. Transmission-mode approach has been used for sensing the liquid/gas two-phase flow, which is a kind of strongly inhomogeneous ...
    • Ultrasound processing circuitry for ultrasonic tomography 

      Nor Muzakkir, Nor Ayob; Mohd Hafiz, Fazalul Rahiman; Sazali, Yaacob; Ruzairi, Abdul Rahim (Universiti Malaysia Perlis, 2009-10-11)
      The development of an ultrasonic transmission tomography system is described. The system is intended for the imaging of two component flows (such as gas/water) inside pipes of industrial processes. Transmission-mode ...