Anas Mohd Noor
Browse by
About Anas Mohd Noor
Anas Mohd Noor is currently a Senior Lecturer at Faculty of Electronic Engineering Technology, Universiti Malaysia Perlis
He was formerly from School of Mechatronic Engineering
ORCID ID: https://orcid.org/0000-0002-0410-3635
Scopus Author ID: 57190394249
Email: Anas Mohd Noor
Research Interests
Electronic System
Embedded System
Signal Processing
Sensors and Application
This page provides access to research works by Anas bin Mohd Noor, currently a Lecturer of , Universiti Malaysia Perlis (UniMAP).
Recent Submissions
-
A study of Biomagnetic Stimulation for Transcranial application
(IOP Publishing, 2019)Biomagnetic stimulation is a treatment uses the application of magnetic field principle for a therapeutic purpose. This non-invasive therapeutic technique use low frequency electromagnetic field which is less than 10 MHz. ... -
Development of tetrapolar conductivity cell for liquid measurement application
(IFSA Publishing, S. L., 2014-03)This paper deals with the development of a liquid measuring instrumentation using the popular tetrapolar electrode configuration. The system consists of four-electrode ring shape using Cromium metal plate and a small ... -
Development of a non-invasive bio-acoustics measurement system for assessing articular cartilage knee joint problem
(Penerbit UTM Press, 2014)A technique in measuring and recording of bio-acoustics signals for the assessment of physiological of knee joint articular cartilage conditions has been developed. Currently, invasive technique such as knee arthroscopy ... -
Development of bioreactor system for generating three dimensional (3D) tissue engineering
(Trans Tech Publications, 2013)This study, perfusion bioreactor has been employed for generating a three dimensional (3D) tissue engineering. In flow perfusion culture, the culture medium is forced through the internal porous network of the scaffold. ... -
Non-invasive blood glucose measurement Measurement of bioelectrical signal
(IEEE Conference Publications, 2012)Impedance of blood relatively affected by blood glucose concentration. Blood electrical impedance value is varied with the content of blood glucose in a human body. This characteristic between glucose and electrical impedance ... -
Development of non-invasive blood-glucose measurement system A bio-impedance approach
(IEEE Conference Publications, 2013)Diabetes is already the world’s most costly epidemic. Current glucose monitoring are invasive, which requires painful procedures and not reliable for long term usage. Impedance of human skin provides details about physiological ... -
Non-invasive blood glucose measurement Application of near infrared optical measurement
(IEEE Conference Publications, 2012)In clinical practice currently, blood glucose is measured using an invasive techniques which is unsuitable and having risky of infection in the patient since the finger is pricked three to five times a day. In this study, ... -
A three dimensional finite element of Anterior Cruciate Ligament model
(Trans Tech Publications, 2013)Anterior Cruciate Ligament (ACL) is of the major knee ligament. A three dimensional model that reflects the geometric characteristics of the human ACL developed to explore and analyze finite element parameters such as ... -
Development of a low cost precision blood resistivity measurement device based on Thompson Lampard theorem
(Institute of Electrical and Electronics Engineers (IEEE), 2012-02-27)Certain diseases detection on the hematocrit level in the human blood can be identified based on resistivity or its impedance. Currently, physicians depend on different laboratory tests of blood for diagnosing and monitoring ... -
Ganobuster: Novel, Easy, and Clean Basal Stem Rot Detection System of the Palm Oil Trunk
(INPEX, 2007-06-06)The technology incorporates multi-disciplinary inputs in which data captured through the use of versatile sensors are analyzed using artificial neural networks (ANN) to be translated and presented into profiles considered ... -
Ganobuster: Novel, Easy, and Clean Basal Stem Rot Detection System of the Palm Oil Trunk
(Malaysian Invention and Design Society (MINDS), 2006-05-19)The technology incorporates multi-disciplinary inputs in which data captured through the use of versatile sensors are analyzed using artificial neural networks(ANN) to be translated and presented into profiles considered ... -
Bio e-Nose for Virgin Coconut Oil (VCO) Standardization
(Malaysian Invention and Design Society (MINDS), 2006)To establish Bio e-Nose as a tool to standardize and quality control of VCO.