Now showing items 1-6 of 6

    • Current transformer reaction with linear and non-linear loads 

      Ismail, Daut, Prof. Dr.; Khairul Anuar, Mohd Nor; Indra, Nisja; Shatri, C.; Reza, Mohyin (Institute of Electrical and Electronics Engineers (IEEE), 2010-06-23)
      The used of non-linear loads nowadays in industrial system has increased accordance with the present technology. However, the used of non-linear loads supply more harmonic distortion into the distribution systems. ...
    • Designs of harmonic filtering system for minimizing the harmonic effects and improve the power factor 

      Siew Chan Yi (Universiti Malaysia PerlisSchool of Electrical Systems Engineering, 2008-05)
      Now a day, power quality is becomes more and more important issue. The whole Malaysia energy consumers concerned about the quality of energy they are using, and the consumers are enjoying with the outstanding performance ...
    • Development of minimizing the harmonic distortion and improving the power factor by using PFC FA5501 in 3 phase system 

      Yong Pit Hing (Universiti Malaysia PerlisSchool of Electrical Systems Engineering, 2008-03)
      In this thesis, PFC FFA5501 is introducing to reduce the harmonic and increase the power system of the system. By designing the necessary technique and methodology, the overall Power Factor (PF) and the Total Harmonic ...
    • Harmonic content as the indicator of transformer core saturation 

      Ismail, Daut, Prof. Dr.; Syafruddin, Hassan; Soib, Taib; Risnidar, Chan; Muhammad Irwanto (Institute of Electrical and Electronics Engineers (IEEE), 2010-06-23)
      The paper proposes a measurement method for obtaining the parameters needed to calculate a reliable indicator of the state of transformer core saturation. The major nonlinear effects in transformer core are saturation, ...
    • Harmonic monitoring at UniMAP distributed campus 

      Indra, Nisja; Ismail, Daut, Prof. Dr.; Syafrudin, M.; Risnidar Chan, Bahaudin, Ir.; Surya Hardi, Amrin (Institute of Electrical and Electronics Engineers (IEEE), 2011-06-06)
      This paper an attempt has been made to monitor and analyze the harmonic distortions caused by certain typical non linear loads of an educational institution. The current and voltage harmonic distortion at PCC feeding office ...
    • Harmonic performance of single phase transformer with DC biased 

      Syafruddin, Hasan; Ismail, Daut, Prof. Dr.; Soib, Taib, Prof. Madya Dr.; Dina Maizana, Maiz Ahmad, Ir.; Rosnazri, Ali; Nor Ashbahani, Ashbahani (Universiti Malaysia Perlis (UniMAP)Centre for Graduate Studies, 2010-10-16)
      Direct current (DC) flowing through the earthed neutrals of transformer windings causes a DC component in magnetizing current. Owing to nonlinearity, the waveform of this current is strongly distorted. A high enough ...