Browsing Ismail Daut, Prof. Dr. by Subject "Flux distribution"
Now showing items 1-15 of 15
-
Analysis flux on transformer core lamination assembled with mix between 60o- 45o T-joint using 2DFEM
(Universiti Malaysia Perlis (UniMAP)Institut Matematik Kejuruteraan, 2010-06-02)This paper describes analysis 2DFEM on 100kVA 3phase distribution transformer assembled with mix between 60-45 T-joint and mitred lap corner joint with stagger yoke and limb for one lamination. The simulation involves the ... -
Comparison between the localized power loss and flux distribution in a three phase distribution transformer 100 kva assembled from various type of T-joint geometry with Staggered Yoke
(ACTA Press, 2008-04-02)This paper describes the result of an investigation of the variation of localized power loss and flux distribution in 3-phase transformer cores 100kVA assembled from various types of T-joint geometry. The localized power ... -
Comparison of losses and flux distribution in 3 phase 100 kVA distribution transformers assembled from various type of T-Joint geometry
(Science Publications, 2006)This paper describes results of an investigation of the variation of power loss, building factor, flux leakage and flux distribution in 3-phase model transformer cores assembled from various type of T-joint geometry. The ... -
Comparison on losses and flux distribution among three 3-phase distribution transformers 1000kVA assembled from various amount of layers per stack of transformers core lamination
(Universiti Kuala Lumpur (UniKL), 2007-12-13)This paper describes the results of an investigarion on the effect of different amount of layers per stack of core lamination in the three of 3 phase distribution transformers 1000kVA. The investigation involves the variant ... -
Comparison on losses and flux distribution between two 3-phase distribution transformers 1000kVA assembled with air gap and without air gap of transformer core lamination
(Institute of Electrical and Electronics Engineering (IEEE), 2007-12-06)This paper describes the result of an investigation on the effect of air gap of core lamination in two 3-phase distribution transformers 1000kVA. The investigation involves the variation of power loss, building factor, the ... -
Comparison on losses and flux distribution between two of 3 phase distribution transformer 1000kVA assembled with regular and irregular stack of transformer core lamination
(Universiti Malaysia Perlis (UniMAP), 2008-03-10)This paper describe the result of an investigation on the effect of different stack of core lamination in the two of 3 phase distribution transformer 1000kVA. The investigation involves the variation of power loss, building ... -
Comparison on losses and flux distribution between two of 3 phase distribution transformer 1000kVA assembled with regular and irregular stack of transformer core lamination
(The Malaysian Research Group (MRG), 2007-12-06)This paper describe the result of an investigation on the effect of different stack of core lamination in the two of 3 phase distribution transformer 1000kVA. The investigation involves the variation of power loss, building ... -
Comparison on losses and flux distribution between two of 3 phase distribution transformer core 3000 kVA assembled with different angle of T-Joint
(Malaysia - Japan University Center (MJUC), 2007-11-15)Thia paper describes the results of an investigation on the effect of the use of different angle of T-Joint in two models of 3 phase distribution transformer with capacity of 3000 kVA. The first model uses 3 phase distribution ... -
Flux simulation on 100kVA three-phase transformer core
(Praise Worthy Prize S.r.l., 2010-06)This paper describes the simulation of flux distribution on 100kVA 3 phase distribution transformer assembled with 60°-45° T-joint and mitred lap corner joint with stagger yoke and limb. The core that being used is 3% ... -
Measurement of flux density distribution on 100kVA 3-Phase distribution transformer assembled with 90° T-joint and mitred lap corner joint with stagger yoke by using search coil
(Institute of Electrical and Electronics Engineers (IEEE), 2008-12-01)This paper describes the result of measurement of flux distribution on 100kVA 3phase distribution transformer assembled with 90° T-joint and mitred lap corner joint with stagger yoke. The measurement involves the variation ... -
Measurement of overall power loss and flux leakage in M4 grain-oriented silicon iron assembled with 45o T-joint of three phase transformer core
(Institute of Electrical and Electronics Engineers (IEEE), 2010-06-23)In this paper, the result of an investigation on the effect of using M4 Grain-Oriented Silicon Iron core material to the 100kVA three phase distribution transformers has been analyzed. The investigation includes the variation ... -
Predicting an investigation of flux distribution in three phase induction motor stators by using different stator slot sizes
(Universiti Malaysia Perlis (UniMAP)Centre for Graduate Studies, 2010-09-16)The predicting of different stator slot sizes on flux distribution in three phase induction motor is presented. For both stator models, the maximum flux density is found near the tooth tip and minimum towards the outer ... -
Predicting the localized flux distribution in three phase induction motor between different stator slot size
(Institute of Electrical and Electronics Engineers (IEEE), 2011-06-06)A three phase induction motor differences of stator slot size is investigated in terms of its localized flux distribution. The search coil induced voltage method is used to analyze the flux distribution in the stator core. ... -
Simulation of flux distribution and loss calculation at three-phase transformer core with the mix 60o-45o T-joint
(Universiti Malaysia Perlis (UniMAP)Centre for Graduate Studies, 2010-10-16)This paper describes the result of simulation of flux distribution on 100kVA 3phase distribution transformer assembled with 23o T-joint and mitred lap corner joint with stagger yoke and limb for one lamination. The ... -
Transformers design with T-joint 45º for minimum power loss
(Universiti Malaysia PerlisSchool of Electrical Systems Engineering, 2008-03)The transformer is a static device and has rotational losses. When transformers transfer power, they do so with a minimum of loss. Transformers are widely used in many sectors such as industrial sector and commercial ...