Building factor of Grain-Oriented Silicon Iron (3% SiFe) with different thickness on 100kVA three phase distribution transformer core
(Trans Tech Publications., 2012-03)
The power loss in laminated transformer cores is always greater than the nominal loss of the electrical steel laminations, by a factor known as the building factor. This paper discussed result of an investigation towards ...
Simulation of flux distribution and loss calculation at three-phase transformer core with the mix 60o-45o T-joint
(Universiti Malaysia Perlis (UniMAP), 2010-10-16)
This paper describes the result of simulation of flux
distribution on 100kVA 3phase distribution transformer
assembled with 23o T-joint and mitred lap corner joint with
stagger yoke and limb for one lamination. The ...
Measurement of overall power loss for different three phase 100kVA transformer core material
(Institute of Electrical and Electronics Engineers (IEEE), 2011-06-06)
This paper discussed result of an investigation towards the effect of using two different Cold Rolled Grain-Oriented (CRGO) Silicon Iron material to the 100kVA three phase distribution transformer. This experiment used M4 ...
Gradient temperature on 3Phase transformer core with staggered yoke with 90 T-joint
(Universiti Malaysia Pahang (UMP), 2009-06-20)
This paper describes the result of
measurement of localised temperature rise on
100kVA 3phase distribution transformer
assembled with 90o T-joint and mitred lap corner
joint with stagger yoke with overlap length of
10mm. ...
Measurement of overall power loss and flux leakage in M4 grain-oriented silicon iron assembled with 45o T-joint of three phase transformer core
(Institute of Electrical and Electronics Engineers (IEEE), 2010-06-23)
In this paper, the result of an investigation on the effect of using M4 Grain-Oriented Silicon Iron core material to the 100kVA three phase distribution transformers has been analyzed. The investigation includes the variation ...
Normal flux distribution in 45o T-joint of three phase transformer core with staggered yoke and limb10mm
(ACTA Press, 2009-09-07)
This paper describes the result of measurement of normal flux distribution 3-phase 100kVA transformer core assembled with 450T-joint. The investigation involves the variation of normal flux distribution in the core lamination. ...
Analysis flux on transformer core lamination assembled with mix between 60o- 45o T-joint using 2DFEM
(Universiti Malaysia Perlis (UniMAP), 2010-06-02)
This paper describes analysis 2DFEM on 100kVA 3phase distribution transformer assembled with mix between 60-45 T-joint and mitred lap corner joint with stagger yoke and limb for one lamination. The simulation involves the ...